Building Science Series, Issues 21-35 |
From inside the book
Results 1-5 of 100
Page 5
... deflections decreased sub- stantially with time after load removal and loading . FIGURE 2.1–1 . Effect of time on the center deflection of an FRPE tub with warm- and cold- water loads . 352-020 0-70-2 with their lengths transverse to ...
... deflections decreased sub- stantially with time after load removal and loading . FIGURE 2.1–1 . Effect of time on the center deflection of an FRPE tub with warm- and cold- water loads . 352-020 0-70-2 with their lengths transverse to ...
Page 6
... deflections measured b the two end gages . Determine the center deflecti of the sump by subtracting this average settleme from the deflection measured by the center gag After load removal , inspect the surfaces of t tub for cracks and ...
... deflections measured b the two end gages . Determine the center deflecti of the sump by subtracting this average settleme from the deflection measured by the center gag After load removal , inspect the surfaces of t tub for cracks and ...
Page 7
... deflection 5 min after the load is applied shall not be greater than in nor shall the residual center deflection 10 min TABLE 2.2-2 . Static load tests to destruction ( 5- × 10 - in Specimen No. and material Ultimate load , lb PB - 4 ...
... deflection 5 min after the load is applied shall not be greater than in nor shall the residual center deflection 10 min TABLE 2.2-2 . Static load tests to destruction ( 5- × 10 - in Specimen No. and material Ultimate load , lb PB - 4 ...
Page 8
... deflection of the bathtub . The first is to insure that the bath or shower water will drain completely from the tub even though the bather remains in the tub . The second reason is that large deflections may instill a feeling of ...
... deflection of the bathtub . The first is to insure that the bath or shower water will drain completely from the tub even though the bather remains in the tub . The second reason is that large deflections may instill a feeling of ...
Page 9
... Deflection measurements of the rim as well as lateral movements of the front apron were made . Table 2.3-1 describes some of the lateral - movement measurements made on the various tubs . Since de- flections of the rim and lateral ...
... Deflection measurements of the rim as well as lateral movements of the front apron were made . Table 2.3-1 describes some of the lateral - movement measurements made on the various tubs . Since de- flections of the rim and lateral ...
Other editions - View all
Common terms and phrases
applied asphalt ASTM axial load bathtub block brick Building Science Series Bureau of Standards cents Chromel coating color retention Column loads components compressive strength computed construction coordination cracking deg F developed dimensional Dolomite eccentricity effect enamels exposure failure fixture flexural floor load versus Fly Ash FRPE gloss high-bond horizontal industry Kure Beach load versus beam load versus translation louver Major floor load masonry materials maximum measured ment midspan mixer mixing device modular module mortar National Bureau Output Channel percent performance plumbing fixtures Porcelain Enamels Portland Cement precoordination Prestressed Concrete prestressing prisms resistance resistance thermometer shear shear strength shown in figure slab south wind load specifications specimens steel surface temperature tensile strength test results test structure thermistors thermocouples tion vane versus beam deflection VERTICAL DEFLECTION vertical load walls west wind load wind load versus
Popular passages
Page 127 - ABSTRACT (A 200-word or less factual summary of most significant information. If document includes a significant...
Page 6 - In no case does such identification imply recommendation or endorsement by the National Bureau of Standards , nor does it imply that the...
Page 11 - FOR COMPUTER SCIENCES AND TECHNOLOGY conducts research and provides technical services designed to aid Government agencies in improving cost effectiveness in the conduct of their programs through the selection, acquisition, and effective utilization of automatic data processing equipment; and serves as the principal focus...
Page 3 - This report gives findings and recommendations developed during an investigation of performance characteristics for sanitary plumbing fixtures, conducted at the request of the Building Research Advisory Board of the National Academy of Sciences-National Research Council. The...