Building Science Series, Issues 21-35 |
From inside the book
Results 1-5 of 100
Page 7
... dimensions and weights FRPE Rim -. three FRPE units , one enameled - steel tub , and one cast - iron tub . The table is self - explanatory and is presented for information only . Table 2.2-3 is a compilation of various dimensions of all ...
... dimensions and weights FRPE Rim -. three FRPE units , one enameled - steel tub , and one cast - iron tub . The table is self - explanatory and is presented for information only . Table 2.2-3 is a compilation of various dimensions of all ...
Page 8
... Dimensions : ( a ) Length , in . ( b ) Width , in ( c ) Rim Height , in .. ( d ) Top to Floor , in . ( e ) Water Bead , in .. Sump dimensions : ( a ) Depth , in .. ( b ) Depth , in.b. ( c ) Length , in .. ( d ) Width , at widest point ...
... Dimensions : ( a ) Length , in . ( b ) Width , in ( c ) Rim Height , in .. ( d ) Top to Floor , in . ( e ) Water Bead , in .. Sump dimensions : ( a ) Depth , in .. ( b ) Depth , in.b. ( c ) Length , in .. ( d ) Width , at widest point ...
Page 16
... Dimension " a " of figure 2.6-3 . FIGURE 2.6-4 . Test for rigidity of assemblies . drain - fitting Δ RADIAL POSITION OF LEVER ARM . 0 +1 SPECIMEN SC - 2 ( STEEL ) 1 1 .2 3 4 .5 1 .6 7 DEFLECTION AT 30 IN . FROM CENTER OF DRAIN HOLE , IN ...
... Dimension " a " of figure 2.6-3 . FIGURE 2.6-4 . Test for rigidity of assemblies . drain - fitting Δ RADIAL POSITION OF LEVER ARM . 0 +1 SPECIMEN SC - 2 ( STEEL ) 1 1 .2 3 4 .5 1 .6 7 DEFLECTION AT 30 IN . FROM CENTER OF DRAIN HOLE , IN ...
Page 29
... dimension . Chip , % -in maximum dimension . • Faint mar . Fine scratches . No. of tests 3343 8333 the convex surfaces ... dimensions of bottles of the same nominal size plus the danger from glass breakage led to the use of an aluminum ...
... dimension . Chip , % -in maximum dimension . • Faint mar . Fine scratches . No. of tests 3343 8333 the convex surfaces ... dimensions of bottles of the same nominal size plus the danger from glass breakage led to the use of an aluminum ...
Page 39
... DIMENSIONS OF HEAT ELEMENT IN TEST TUB MATERIAL : Type L Copper Water Tube A. steam trap safe for use at line pressure - opens to dis- charge condensate into test tub ; B , thermostat and recorder sensor location approximately mid ...
... DIMENSIONS OF HEAT ELEMENT IN TEST TUB MATERIAL : Type L Copper Water Tube A. steam trap safe for use at line pressure - opens to dis- charge condensate into test tub ; B , thermostat and recorder sensor location approximately mid ...
Other editions - View all
Common terms and phrases
applied asphalt ASTM axial load bathtub block brick Building Science Series Bureau of Standards cents Chromel coating color retention Column loads components compressive strength computed construction coordination cracking deg F developed dimensional Dolomite eccentricity effect enamels exposure failure fixture flexural floor load versus Fly Ash FRPE gloss high-bond horizontal industry Kure Beach load versus beam load versus translation louver Major floor load masonry materials maximum measured ment midspan mixer mixing device modular module mortar National Bureau Output Channel percent performance plumbing fixtures Porcelain Enamels Portland Cement precoordination Prestressed Concrete prestressing prisms resistance resistance thermometer shear shear strength shown in figure slab south wind load specifications specimens steel surface temperature tensile strength test results test structure thermistors thermocouples tion vane versus beam deflection VERTICAL DEFLECTION vertical load walls west wind load wind load versus
Popular passages
Page 127 - ABSTRACT (A 200-word or less factual summary of most significant information. If document includes a significant...
Page 6 - In no case does such identification imply recommendation or endorsement by the National Bureau of Standards , nor does it imply that the...
Page 11 - FOR COMPUTER SCIENCES AND TECHNOLOGY conducts research and provides technical services designed to aid Government agencies in improving cost effectiveness in the conduct of their programs through the selection, acquisition, and effective utilization of automatic data processing equipment; and serves as the principal focus...
Page 3 - This report gives findings and recommendations developed during an investigation of performance characteristics for sanitary plumbing fixtures, conducted at the request of the Building Research Advisory Board of the National Academy of Sciences-National Research Council. The...