Page 64
... wall surrounds some cases cracking of the edge strip was observed . observed cracks did not extend into the part of the fix intended to be visible after installation of the bathr walls . One manufacturer recommended screws for this pose ...
... wall surrounds some cases cracking of the edge strip was observed . observed cracks did not extend into the part of the fix intended to be visible after installation of the bathr walls . One manufacturer recommended screws for this pose ...
Page iv
... walls 40 5.18 . Fire wall 41 9.21 . Test No. 8 , west wind load versus trans- lation 58 5.19 . Fire wall ( partially dismantled ) 42 5.20 . Exterior wall details 43 9.22 . Effect of vertical loads on east - west hori- zontal translation ...
... walls 40 5.18 . Fire wall 41 9.21 . Test No. 8 , west wind load versus trans- lation 58 5.19 . Fire wall ( partially dismantled ) 42 5.20 . Exterior wall details 43 9.22 . Effect of vertical loads on east - west hori- zontal translation ...
Page 7
... Walls Figure 5.18 shows a typical cross section of the fire walls . The walls are installed in every second bay in the " short " direction of the building ( N - S in the test structure ) . These walls are continuous in all spaces ...
... Walls Figure 5.18 shows a typical cross section of the fire walls . The walls are installed in every second bay in the " short " direction of the building ( N - S in the test structure ) . These walls are continuous in all spaces ...
Page 8
... walls is illustrated in figures 5.24 and 5.25 , respectively . It comprises a part of the complete structure , made up of full - scale components and erected in the laboratory . The test structure as part of the complete structure is ...
... walls is illustrated in figures 5.24 and 5.25 , respectively . It comprises a part of the complete structure , made up of full - scale components and erected in the laboratory . The test structure as part of the complete structure is ...
Page 9
... wall " as described in section 5.1.3 ( 3 ) . All channels for the wall system were at- tached by power - actuated fasteners to the floor slab and the structural frame . Vapor seals and insulation between walls were omitted since these ...
... wall " as described in section 5.1.3 ( 3 ) . All channels for the wall system were at- tached by power - actuated fasteners to the floor slab and the structural frame . Vapor seals and insulation between walls were omitted since these ...
Other editions - View all
Common terms and phrases
applied asphalt ASTM axial load bathtub block brick Building Science Series Bureau of Standards cents Chromel coating color retention Column loads components compressive strength computed construction coordination cracking deg F developed dimensional Dolomite eccentricity effect enamels exposure failure fixture flexural floor load versus Fly Ash FRPE gloss high-bond horizontal industry Kure Beach load versus beam load versus translation louver Major floor load masonry materials maximum measured ment midspan mixer mixing device modular module mortar National Bureau Output Channel percent performance plumbing fixtures Porcelain Enamels Portland Cement precoordination Prestressed Concrete prestressing prisms resistance resistance thermometer shear shear strength shown in figure slab south wind load specifications specimens steel surface temperature tensile strength test results test structure thermistors thermocouples tion vane versus beam deflection VERTICAL DEFLECTION vertical load walls west wind load wind load versus
Popular passages
Page 127 - ABSTRACT (A 200-word or less factual summary of most significant information. If document includes a significant...
Page 6 - In no case does such identification imply recommendation or endorsement by the National Bureau of Standards , nor does it imply that the...
Page 11 - FOR COMPUTER SCIENCES AND TECHNOLOGY conducts research and provides technical services designed to aid Government agencies in improving cost effectiveness in the conduct of their programs through the selection, acquisition, and effective utilization of automatic data processing equipment; and serves as the principal focus...
Page 3 - This report gives findings and recommendations developed during an investigation of performance characteristics for sanitary plumbing fixtures, conducted at the request of the Building Research Advisory Board of the National Academy of Sciences-National Research Council. The...