The Elements of Bacteriological Technique: A Laboratory Guide for the Medical, Dental, and Technical StudentW.B. Saunders, 1902 - 361 pages |
From inside the book
Results 1-5 of 92
Page 17
... requirements , viz .: 1. 18 by 1.5 cm . , to contain media for ordinary tube cultivations . 2. 18 by 1.3 cm . , to contain media used for pouring plate cultivations , and also for holding sterile " swabs . " 3. 18 by 2 cm . , to contain ...
... requirements , viz .: 1. 18 by 1.5 cm . , to contain media for ordinary tube cultivations . 2. 18 by 1.3 cm . , to contain media used for pouring plate cultivations , and also for holding sterile " swabs . " 3. 18 by 2 cm . , to contain ...
Page 20
... required , viz .: 1. Pipettes of 1 c.c. capacity graduated in o.1 c.c. 2. Pipettes of 1 c.c. capacity graduated in 0.01 c.c. ( Fig . 9 , a ) . 3. Pipettes of 10 c.c. capacity graduated in o.1 c.c. 20 GLASS APPARATUS IN COMMON USE .
... required , viz .: 1. Pipettes of 1 c.c. capacity graduated in o.1 c.c. 2. Pipettes of 1 c.c. capacity graduated in 0.01 c.c. ( Fig . 9 , a ) . 3. Pipettes of 10 c.c. capacity graduated in o.1 c.c. 20 GLASS APPARATUS IN COMMON USE .
Page 32
... requirements of the bac- teriological laboratory , many of these agents , such as electricity , sunlight , etc. , are practically useless ; whilst others are limited in their applications , or are so well suited to particular purposes ...
... requirements of the bac- teriological laboratory , many of these agents , such as electricity , sunlight , etc. , are practically useless ; whilst others are limited in their applications , or are so well suited to particular purposes ...
Page 45
... Required.- 1. Separatory funnel containing the unfiltered fluid . Fig . 24. - Filter candle . 2. Sterile filter candle , the open end fitted with a rubber stopper perforated to receive the delivery tube of the sep- aratory funnel , and ...
... Required.- 1. Separatory funnel containing the unfiltered fluid . Fig . 24. - Filter candle . 2. Sterile filter candle , the open end fitted with a rubber stopper perforated to receive the delivery tube of the sep- aratory funnel , and ...
Page 55
... required . The mechanical stage should be fitted with three ( removable ) screw studs , so that if necessary a Vernier finder ( Fig . 34 , D ) , such as is usually fitted to this class of stage , or a Maltwood finder , may be used . 6 ...
... required . The mechanical stage should be fitted with three ( removable ) screw studs , so that if necessary a Vernier finder ( Fig . 34 , D ) , such as is usually fitted to this class of stage , or a Maltwood finder , may be used . 6 ...
Other editions - View all
Common terms and phrases
absolute alcohol acid anaerobically aniline animal Apparatus Required aqueous solution Bacillus bacteria beaker blood-serum boiling bottle bouillon Bunsen Bunsen burner c.c. capacity cell cent Clinical Cloth colonies colour containing cotton-wool plug cover-slip films cubic centimetre culture tube cylinder dilute Diseases dissolve distilled water Edition emulsify emulsion filter candle Filter through papier flame flask fluid forceps fuchsin funnel gelatine gentian violet glass tubing glucose glucose formate Gram's method grammes growth guinea-pig Half Morocco Handsome octavo hanging-drop heat incubate incubate at 37 Inoculate inoculum meat extract Medicine medium micrometer NaOH nutrient agar nutrient bouillon nutrient gelatine octavo organisms papier Chardin peptone pipette Professor quantity reaction Remove sample sections serum Sheep or Half slide soda solution spores steamer at 100 sterile sterile capsules sterile pipettes sterilise stopper surface Surgery temperature test-tube tion tissue tube cultivations tubes of nutrient twenty minutes vide water-bath Weigh xylol