The Elements of Bacteriological Technique: A Laboratory Guide for the Medical, Dental, and Technical StudentW.B. Saunders, 1902 - 361 pages |
From inside the book
Results 1-5 of 42
Page 12
... completing the volume from the point of view of the medical and dental student , the work has been arranged to allow of its use as a laboratory guide by the technical student generally , whether of brewing , dairying , or agriculture ...
... completing the volume from the point of view of the medical and dental student , the work has been arranged to allow of its use as a laboratory guide by the technical student generally , whether of brewing , dairying , or agriculture ...
Page 27
... Complete the cleaning as described under " new pipettes . " 22mm2 7/8 " 2 38 X 19mm . 12 X 34 19mm2 . 16mm2 3/4 5/8 " 2 Fig . 15. - Slides and cover - slips , actual size . Slides and cover - slips ( Fig . 15 ) , when first purchased ...
... Complete the cleaning as described under " new pipettes . " 22mm2 7/8 " 2 38 X 19mm . 12 X 34 19mm2 . 16mm2 3/4 5/8 " 2 Fig . 15. - Slides and cover - slips , actual size . Slides and cover - slips ( Fig . 15 ) , when first purchased ...
Page 33
... complete sterilisation by other processes . To this class belong : 1. Lysol , 2 per cent . solution ; 2. Perchloride of mercury , o.1 per cent . solution ; 3. Carbolic acid , 5 per cent . solution ; 4. Absolute alcohol ; 5. Ether ; 6 ...
... complete sterilisation by other processes . To this class belong : 1. Lysol , 2 per cent . solution ; 2. Perchloride of mercury , o.1 per cent . solution ; 3. Carbolic acid , 5 per cent . solution ; 4. Absolute alcohol ; 5. Ether ; 6 ...
Page 46
... the separatory funnel to the filter candle by means of the perforated rubber stopper ( Fig . 27 ) . 4. Open the tap of the funnel , and exhaust. Fig . 25. - Geryk air pump . Fig . 30. - Microscope complete . 46 METHODS OF STERILISATION .
... the separatory funnel to the filter candle by means of the perforated rubber stopper ( Fig . 27 ) . 4. Open the tap of the funnel , and exhaust. Fig . 25. - Geryk air pump . Fig . 30. - Microscope complete . 46 METHODS OF STERILISATION .
Page 47
... complete . 5. Adjust a screw clamp to the pressure tubing attached to the lateral branch of the filter flask ; screw it up tightly , and disconnect the acid wash- bottle . 6. Attach the air filter to the open end of the pressure tubing ...
... complete . 5. Adjust a screw clamp to the pressure tubing attached to the lateral branch of the filter flask ; screw it up tightly , and disconnect the acid wash- bottle . 6. Attach the air filter to the open end of the pressure tubing ...
Other editions - View all
Common terms and phrases
absolute alcohol acid anaerobically aniline animal Apparatus Required aqueous solution Bacillus bacteria beaker blood-serum boiling bottle bouillon Bunsen Bunsen burner c.c. capacity cell cent Clinical Cloth colonies colour containing cotton-wool plug cover-slip films cubic centimetre culture tube cylinder dilute Diseases dissolve distilled water Edition emulsify emulsion filter candle Filter through papier flame flask fluid forceps fuchsin funnel gelatine gentian violet glass tubing glucose glucose formate Gram's method grammes growth guinea-pig Half Morocco Handsome octavo hanging-drop heat incubate incubate at 37 Inoculate inoculum meat extract Medicine medium micrometer NaOH nutrient agar nutrient bouillon nutrient gelatine octavo organisms papier Chardin peptone pipette Professor quantity reaction Remove sample sections serum Sheep or Half slide soda solution spores steamer at 100 sterile sterile capsules sterile pipettes sterilise stopper surface Surgery temperature test-tube tion tissue tube cultivations tubes of nutrient twenty minutes vide water-bath Weigh xylol