Page 28
... stopper tightly . NOTE . After once being placed in the chromic acid , the cover - slips must on no account be touched by the fingers . Used Slides and Cover - slips . - Used slides with the mounted cover - slip preparations , and cover ...
... stopper tightly . NOTE . After once being placed in the chromic acid , the cover - slips must on no account be touched by the fingers . Used Slides and Cover - slips . - Used slides with the mounted cover - slip preparations , and cover ...
Page 32
... stoppers , etc. ) . 3. Streaming steam at 100 ° C. ( for the sterilisation of media ) . 4. Superheated steam at 115 ° C. or 120 ° C. ( for the disinfection of contaminated articles and old culti- vations of bacteria ) . Filters.- 1 ...
... stoppers , etc. ) . 3. Streaming steam at 100 ° C. ( for the sterilisation of media ) . 4. Superheated steam at 115 ° C. or 120 ° C. ( for the disinfection of contaminated articles and old culti- vations of bacteria ) . Filters.- 1 ...
Page 45
... stopper perforated to receive the delivery tube of the sep- aratory funnel , and its neck passed through a large rubber washer ( a ) which fits the mouth of the filter flask . 3. Sterile filter flask of suitable size , for the reception ...
... stopper perforated to receive the delivery tube of the sep- aratory funnel , and its neck passed through a large rubber washer ( a ) which fits the mouth of the filter flask . 3. Sterile filter flask of suitable size , for the reception ...
Page 46
... separatory funnel to the filter candle by means of the perforated rubber stopper ( Fig . 27 ) . 4. Open the tap of the funnel , and exhaust. Fig . 25. - Geryk air pump . Fig . 30. - Microscope complete . 46 METHODS OF STERILISATION .
... separatory funnel to the filter candle by means of the perforated rubber stopper ( Fig . 27 ) . 4. Open the tap of the funnel , and exhaust. Fig . 25. - Geryk air pump . Fig . 30. - Microscope complete . 46 METHODS OF STERILISATION .
Page 48
... stopper into the mouth of the separatory funnel and secure in position with copper wire ; next fit a piece of glass tubing through the stopper , and connect the external orifice with an air - pressure pump of some kind ( an ordinary ...
... stopper into the mouth of the separatory funnel and secure in position with copper wire ; next fit a piece of glass tubing through the stopper , and connect the external orifice with an air - pressure pump of some kind ( an ordinary ...
Other editions - View all
Common terms and phrases
absolute alcohol acid anaerobically aniline animal Apparatus Required aqueous solution Bacillus bacteria beaker blood-serum boiling bottle bouillon Bunsen Bunsen burner c.c. capacity cell cent Clinical Cloth colonies colour containing cotton-wool plug cover-slip films cubic centimetre culture tube cylinder dilute Diseases dissolve distilled water Edition emulsify emulsion filter candle Filter through papier flame flask fluid forceps fuchsin funnel gelatine gentian violet glass tubing glucose glucose formate Gram's method grammes growth guinea-pig Half Morocco Handsome octavo hanging-drop heat incubate incubate at 37 Inoculate inoculum meat extract Medicine medium micrometer NaOH nutrient agar nutrient bouillon nutrient gelatine octavo organisms papier Chardin peptone pipette Professor quantity reaction Remove sample sections serum Sheep or Half slide soda solution spores steamer at 100 sterile sterile capsules sterile pipettes sterilise stopper surface Surgery temperature test-tube tion tissue tube cultivations tubes of nutrient twenty minutes vide water-bath Weigh xylol