The Principles of hygieneW.B. Saunders, 1901 - 495 pages |
From inside the book
Results 1-5 of 54
Page 11
... Cubic Space , 61. - General Rules for Ventilation , 63. - Natural Ventilation , 63. - Arrangements in Natural Ventilation , 65. - Artificial Ventilation , 74. - Removal of Dust , 78 . HEATING CHAPTER III . Loss of Heat from Buildings ...
... Cubic Space , 61. - General Rules for Ventilation , 63. - Natural Ventilation , 63. - Arrangements in Natural Ventilation , 65. - Artificial Ventilation , 74. - Removal of Dust , 78 . HEATING CHAPTER III . Loss of Heat from Buildings ...
Page 13
... Cubic Space and Floor Space , 270. - Relation of Window Space to Floor Space , 272.- Lighting , 273. - The Position of Blackboards , 274. - Corridors , Cloak - rooms , and Wardrobes , 274. - Ventilation , 275. - Heating , 276. - Water ...
... Cubic Space and Floor Space , 270. - Relation of Window Space to Floor Space , 272.- Lighting , 273. - The Position of Blackboards , 274. - Corridors , Cloak - rooms , and Wardrobes , 274. - Ventilation , 275. - Heating , 276. - Water ...
Page 33
... cubic meters of air ; the maximum amount being about 3.5 milligrams . This gas is usually absent from the air of cities and the air which has passed through localities which are thickly populated . It is found in the atmosphere over ...
... cubic meters of air ; the maximum amount being about 3.5 milligrams . This gas is usually absent from the air of cities and the air which has passed through localities which are thickly populated . It is found in the atmosphere over ...
Page 40
... cubic meter . It varies with the temperature , and it may be computed from the readings . of the wet and dry - bulb thermometers by the use of tables . Relative Humidity . - Complete saturation of the air being taken as 100 , any degree ...
... cubic meter . It varies with the temperature , and it may be computed from the readings . of the wet and dry - bulb thermometers by the use of tables . Relative Humidity . - Complete saturation of the air being taken as 100 , any degree ...
Page 50
... cubic centimeters , and to contain 4 per cent . of carbon dioxid , and that 17 respirations are taken every minute , then the carbon dioxid excreted in one hour is 500 X 0.04 X 17 X 60 = 20.4 liters , or 489.6 liters in twenty - four ...
... cubic centimeters , and to contain 4 per cent . of carbon dioxid , and that 17 respirations are taken every minute , then the carbon dioxid excreted in one hour is 500 X 0.04 X 17 X 60 = 20.4 liters , or 489.6 liters in twenty - four ...
Common terms and phrases
ammonia amount animals antitoxin bacillus bacteria baggage bichlorid of mercury Board of Health body boiling calories carbolic acid carbon dioxid cargo cause cent centimeters cholera clean Clinical Cloth color contained cubic centimeters cubic meters death-rate deaths diet digestion diphtheria discharged disinfection dust Edition effects epidemic exposure filter filtration Fomites formaldehyd fresh air grams heat Hospital hygienic immunity important impurities infected infectious diseases influence inspection kilograms liters means meat Medical Medicine method milk mosquitoes nature nitrogen octavo organic matter oxygen passengers persons pipe polluted port prevent produced Professor proteid purification quarantine quarantine officer regulations removed salts sanitary scarlet fever sewage small-pox soil solution of bichlorid steam steerage substances sulphur dioxid supply surface Surgery tank temperature Text-Book tion tuberculosis typhoid fever typhus fever United vaccination vegetable ventilation vessel water-supply weight yellow fever